ZGW1-1.5/3150 DC مفتاح الفصل (3150A)
المواصفات الفنية
| الطراز | ZGW1-1.5/3150 |
|---|---|
| المعيار | IEC 61992-3 (DC مفتاح الفصلs for railway fixed installations) and metro DC traction power supply technical conditions |
| الجهد المقنن | 1.5kV DC |
| سرعة التصميم | N/A (fixed installation equipment) |
| الخامات | Dedicated DC arc-extinguishing contact system; مطلي بالجلفن الساخن steel structure; high-strength insulation |
| التركيب | Mounted in traction substations or trackside boxes; motorized or manual operation |
The ZGW1-1.5/3150 is a 1.5kV DC, 3150A outdoor مفتاح الفصل designed for electrical isolation in metro and urban rail DC traction power supply systems. It isolates sections of the 1500V DC overhead contact system for maintenance and operational switching.
The switch is designed with reference to IEC 61992-3 (Railway applications — Fixed installations — DC switchgear — Part 3: مفتاح الفصلs, switch-مفتاح الفصلs and earthing switches) and relevant metro DC traction power supply technical specifications. A dedicated DC arc-extinguishing contact system ensures reliable breaking under DC load conditions; the مطلي بالجلفن الساخن steel structure and high-strength insulation suit long-term outdoor service from -40°C to +70°C at altitudes up to 4,000 m.
Installation options include mounting inside traction substations or in trackside boxes, with motorized or manual operating mechanisms available to match the automation level of the line.
شركة خنان تشوانغويت لمعدات السكك الحديدية المحدودة supplies the ZGW1 series with type test documentation and engineering support for metro projects worldwide.
Frequently Asked Questions
What is a DC مفتاح الفصل used for in metro systems?
It isolates sections of the 1500V DC traction power network — for example at substations or between line sections — so maintenance can be performed safely without de-energizing the whole line.
Which standard does the ZGW1-1.5/3150 follow?
It is designed with reference to IEC 61992-3 for DC مفتاح الفصلs, plus metro DC traction power supply technical conditions.
Motorized or manual operation?
Both are available. Motorized mechanisms support remote control and automation retrofits; manual mechanisms suit simpler installations.
الأداء
ظروف التشغيل
Long-term outdoor service in metro DC traction power environments from -40°C to +70°C, altitudes to 4,000 m.
الأداء الميكانيكي
Hot-dip galvanized steel frame with high-strength عازلs; robust mechanism for frequent switching duty.
الأداء الكهربائي
Dedicated DC arc-extinguishing contacts provide reliable breaking at 1500V DC / 3150A, designed per IEC 61992-3.
التطبيقات
Metro Substations
DC isolation inside traction substations.
Trackside Boxes
Section isolation along the line in compact enclosures.
Outdoor Service
Galvanized structure for open-air installations.
المناطق الباردة
Operation down to -40°C.